1.
Compr Rev Food Sci Food Saf ; 23(3): e13348, 2024 May.
Article in English | MEDLINE | ID: mdl-38720587

ABSTRACT

Listeria monocytogenes biofilms formed on food-contact surfaces within food-processing facilities pose a significant challenge, serving as persistent sources of cross-contamination. In this review, we examined documented cases of foodborne outbreaks and recalls linked to L. monocytogenes contamination on equipment surfaces and in the food production environment, provided an overview of the prevalence and persistence of L. monocytogenes in different food-processing facilities, and discussed environmental factors influencing its biofilm formation. We further delved into antimicrobial interventions, such as chemical sanitizers, thermal treatments, biological control, physical treatment, and other approaches for controlling L. monocytogenes biofilms on food-contact surfaces. This review provides valuable insights into the persistent challenge of L. monocytogenes biofilms in food processing, offering a foundation for future research and practical strategies to enhance food safety.


Subject(s)
Biofilms , Food Microbiology , Listeria monocytogenes , Listeria monocytogenes/physiology , Biofilms/growth & development , Food Handling/methods , Food Contamination/prevention & control , Equipment Contamination/prevention & control
2.
J Hosp Infect ; 143: 1-7, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38529779

ABSTRACT

BACKGROUND: Using robots to handle medical devices in the decontamination area of the Central Sterile Supply Department (CSSD) can reduce risks and address staff shortages. The gripper design must allow reliable cleaning using standard CSSD procedures to avoid build-up of biofilms and possible cross-contamination between different instrument trays and the gripper's functionality. This study explores the design of the robot's gripper regarding cleanability, aiming to determine whether successful cleaning can be achieved even after prolonged drying for a working shift of 8 h. METHODS: We optimized a gripper for cleanability and used it to assess the spread of different test soils depending on different forms of motion. Subsequently, we analysed the cleanability using sheep's blood as test soil, reprocessing the gripper in different assembly configurations after 4 and 8 h of drying, and measuring residual protein. FINDINGS: Based on our investigations, we documented the spread of contamination depending on the type of motion of the gripper's components. Sheep's blood exhibited the highest dispersion among the test soils, permeating through thin crevices. Importantly, all samples displayed residual protein levels below the warning threshold, irrespective of drying time and gripper disassembly or cleaning position. Cleaning in a device-specific optimized position achieved results comparable to cleaning the disassembled individual components. CONCLUSIONS: These findings indicate that cleaning even after one working shift of 8 h and without the labour-intensive disassembly of the gripper is feasible, supporting the future use of robots to handle contaminated medical devices in the CSSD decontamination area.


Subject(s)
Robotics , Humans , Decontamination/methods , Equipment Contamination/prevention & control , Surgical Instruments , Soil
3.
Ultrasound Med Biol ; 50(6): 775-778, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38485533

ABSTRACT

The COVID-19 pandemic highlighted the importance of infection prevention and control measures for all medical procedures, including ultrasound examinations. As the use of ultrasound increases across more medical modalities, including point-of-care ultrasound, so does the risk of possible transmission from equipment to patients and patients to patients. This is particularly relevant for endocavity transducers, such as trans-vaginal, trans-rectal and trans-oesophageal, which could be contaminated with organisms from blood, mucosal, genital or rectal secretions. This article proports to update the WFUMB 2017 guidelines which focussed on the cleaning and disinfection of trans-vaginal ultrasound transducers between patients.


Subject(s)
COVID-19 , Disinfection , Equipment Contamination , Transducers , Ultrasonography , Humans , Ultrasonography/methods , Ultrasonography/instrumentation , COVID-19/transmission , COVID-19/prevention & control , Equipment Contamination/prevention & control , Disinfection/methods , SARS-CoV-2 , Infection Control/methods , Infection Control/standards , Practice Guidelines as Topic , Point-of-Care Systems
4.
Am J Infect Control ; 52(6): 635-643, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38408542

ABSTRACT

BACKGROUND: Outbreaks linked to inadequate endoscope drying have infected numerous patients, and current standards and guidelines recommend at least 10 minutes of forced air for drying channels. This study evaluated a new forced-air drying system (FADS) for endoscopes. METHODS: Drying was assessed using droplet detection cards; visual inspection of air/water connectors, suction connectors, and distal ends; and borescope examinations of endoscope interiors. Assessments were performed after automated endoscope reprocessor (AER) alcohol flush and air purge cycles and after 10-minute FADS cycles. RESULTS: Researchers evaluated drying during encounters with 22 gastroscopes and 20 colonoscopes. After default AER alcohol and air purge cycles, 100% (42/42) of endoscopes were still wet. Substantial fluid emerged from distal ends during the first 15 seconds of the FADS cycle, and droplets also emerged from air/water and suction connectors. Following FADS cycle completion, 100% (42/42) were dry, with no retained fluid detected by any of the assessment methods. CONCLUSIONS: Multiple endoscope ports and channels remained wet after AER cycles intended to aid in drying but were dry after the FADS cycle. This study reinforced the need to evaluate the effectiveness of current drying practices and illustrated the use of practical tools in a real-world setting.


Subject(s)
Endoscopes , Humans , Endoscopes/microbiology , Desiccation/methods , Disinfection/methods , Disinfection/standards , Equipment Contamination/prevention & control
5.
Biomed Instrum Technol ; 58(1): 25-33, 2024.
Article in English | MEDLINE | ID: mdl-38377297

ABSTRACT

Objective: Borescope examinations of endoscope channels are commonly described in literature, but no studies on surgical instrument lumen inspection have been published recently. Inadequately processed surgical instruments have been implicated in patient infections. This study assessed the utility of borescopes for inspecting surgical instruments. Methods: The study team inspected and photographed sterilized, patient-ready arthroscopic shaver handpieces and suction tips using a tablet camera and borescopes to characterize internal anatomy, defects found in lumens, and the impact of recleaning on debris or residues. Results: Ten suctions and eight shavers were inspected. All suctions had internal ridges and suction holes that were perpendicular to the lumen. All shavers had visible ridges, elbows, and lever mechanisms inside lumens. Of the 18 instruments, 16 (88%) had internal features that appeared rough or jagged and 17 (94%) had visible debris or discoloration in the lumens. Recleaning efforts generally were effective for suctions, but multiple rounds of recleaning with enhanced steps were less effective for shavers, which were replaced. Researchers documented retained soil and brush bristles in several new shavers despite following manufacturer instructions for cleaning and found visible damage and discoloration within five uses. Discussion: This study demonstrated the value of borescope examinations for surgical instrument lumens. Visual inspections identified anatomical features that could influence cleaning effectiveness and detected residual soil, discoloration, and debris in most instruments. The findings suggested that manufacturer cleaning instructions were insufficient and additional cleaning was not always effective. In response, the site's multidisciplinary team strengthened risk assessment protocols and enhanced their cleaning practices.


Subject(s)
Disinfection , Endoscopes , Humans , Pilot Projects , Surgical Instruments , Soil , Equipment Contamination/prevention & control
6.
Front Cell Infect Microbiol ; 14: 1303099, 2024.
Article in English | MEDLINE | ID: mdl-38299116

ABSTRACT

Introduction: The contamination of dental unit waterlines (DUWLs) poses a significant risk of cross-infection in dentistry. Although chemical disinfectants have been effective in reducing number of bacteria, they do have limitations. Methods: This study aimed to investigate the potential of chlorogenic acid, a natural substance with broadspectrum antibacterial properties, for treating DUWLs. Over a period of three months, we analyzed the microbial communities in 149 DUWLs samples collected from 5 dental units using high-throughput pyrophosphate sequencing. Results: The results revealed that chlorogenic acid treatment had a significant impact on the microbial community profile in the DUWLs, with the most significant changes occurring within the first 15 days and stabilization observed in the last 30 days. The predominant genera detected in the samples were Bacteroides, Lactobacillus, Streptococcus, Methylobacterium, and Phreatobacter. Additionally, the relative abundance of certain beneficial bacteria, such as Alloprevotella, Roseburia, and Blautia, increased, while the presence of opportunistic pathogens like Mycobacteria significantly decreased. The functional prediction analysis using the KEGG database indicated a decrease in the pathogenicity of the bacterial community in the DUWLs following chlorogenic acid treatment. Discussion: This study introduces a novel approach for the prevention and treatment of infections associated with dental care.


Subject(s)
Chlorogenic Acid , Equipment Contamination , Chlorogenic Acid/pharmacology , Colony Count, Microbial , Equipment Contamination/prevention & control , Water Microbiology , Bacteria , High-Throughput Nucleotide Sequencing , Biofilms
7.
Aesthet Surg J ; 44(6): 605-611, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38290053

ABSTRACT

BACKGROUND: Bacterial contamination of implants has been linked to biofilm formation and subsequent infection, capsular contracture, and breast implant-associated anaplastic large cell lymphoma. Reducing contamination during implant insertion should therefore reduce biofilm formation disease sequelae. OBJECTIVES: The aim of this study was to compare levels of contamination between preventative techniques. METHODS: A model to simulate the passage of implants through a skin incision was designed that utilized a sterile textured polyvinyl plastic sheet contaminated with Staphylococcus epidermidis. In the first stage of the polyvinyl contamination model, implants were subject to infection-mitigation techniques and passed through the incision, then placed onto horse blood agar plates and incubated for 24 hours. In the second stage of the study the same contamination was applied to human abdominal wall specimens. A 5 cm incision was made through skin and fat, then implants were passed through and levels of contamination were measured as described. RESULTS: Smooth implants grew a mean of 95 colony-forming units (CFUs; approximately 1 CFU/cm2) and textured implants grew 86 CFUs (also approximately 1 CFU/cm2). CFU counts were analyzed by the Mann-Whitney U-test which showed no significant difference between implant types (P < .05); independent-sample t-tests showed a significant difference. The dependent-variable techniques were then compared as groups by one-way analysis of variance, which also showed a significant reduction compared with the control group (P < .01). CONCLUSIONS: This in vitro study has shown the effectiveness of antiseptic rinse and skin/implant barrier techniques for reducing bacterial contamination of breast implants at the time of insertion.


Subject(s)
Biofilms , Breast Implantation , Breast Implants , Prosthesis-Related Infections , Staphylococcus epidermidis , Breast Implants/microbiology , Breast Implants/adverse effects , Humans , Staphylococcus epidermidis/isolation & purification , Breast Implantation/adverse effects , Breast Implantation/instrumentation , Prosthesis-Related Infections/prevention & control , Prosthesis-Related Infections/microbiology , Female , Equipment Contamination/prevention & control , Colony Count, Microbial
8.
J Oncol Pharm Pract ; 30(1): 9-14, 2024 Jan.
Article in English | MEDLINE | ID: mdl-36916178

ABSTRACT

INTRODUCTION: Antineoplastic drugs (ADs) are commonly used pharmaceuticals for anticancer treatments. It has previously been shown that the external surface of drug vials frequently is contaminated with ADs. More than a decade ago methods to prevent occupational exposure were introduced by using plastic coverage of the glass vials or packing vials in a secondary plastic container. The aim of the pilot study was to determine contamination levels of ADs on different parts of AD packaging of two different commercially available drug vials on the Swedish market and to investigate the occurrence of cross contamination of ADs. METHODS: Packagings of gemcitabine (GEM) and 5-fluorouracil (5-FU) were tested by wipe sampling. Five ADs; GEM, 5-FU, cyclophosphamide (CP), ifosfamide and etoposide were quantified using liquid chromatography mass spectrometry. RESULTS: AD contaminations were detected in 69% and 60% of the GEM and 5-FU packaging samples. Highest levels, up to approximately 5 µg/sample, were observed on the glass vials. The protective shrink-wrap of 5-FU vials and the plastic container of GEM were contaminated with low levels of 5-FU and GEM, respectively, and furthermore the 5-FU vials with shrink-wrap were cross-contaminated with GEM. Cross-contamination of CP and GEM was detected on 5-FU vials with plastic shrink-wrap removed. CONCLUSIONS: External contamination of ADs are still present at primary drug packagings on the Swedish market. Protection of AD vials by plastic shrink-wrap or a secondary plastic container does not remove the external contamination levels completely. The presence of cross contamination of ADs on drug packagings was also observed.


Subject(s)
Antineoplastic Agents , Occupational Exposure , Humans , Gemcitabine , Fluorouracil/analysis , Pilot Projects , Drug Packaging , Equipment Contamination/prevention & control , Antineoplastic Agents/analysis , Cyclophosphamide/analysis , Occupational Exposure/prevention & control , Occupational Exposure/analysis , Environmental Monitoring/methods , Drug Contamination/prevention & control
9.
Endoscopy ; 56(3): 198-204, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37848074

ABSTRACT

BACKGROUND: Current duodenoscope reprocessing protocols are insufficient to prevent contamination and require adaptations to prevent endoscopy-associated infections (EAIs). This study aimed to investigate the effect of a new endoscope cleaning brush on the contamination rate of ready-to-use duodenoscopes. METHODS: This retrospective before-and-after intervention study collected duodenoscope surveillance culture results from March 2018 to June 2022. Contamination was defined as ≥1 colony-forming unit of a microorganism of gut or oral origin (MGO). In December 2020, an endoscope cleaning brush with a sweeper design was introduced as an intervention in the manual cleaning of duodenoscopes. A logistic mixed-effects model was used to study the effects of this intervention. RESULTS: Data were collected from 176 culture sets before the new brush's introduction and 81 culture sets afterwards. Pre-introduction, culture sets positive with an MGO comprised 45.5% (95%CI 38.3%-52.8%; 80/176), decreasing to 17.3% (95%CI 10.6%-26.9%; 14/81) after implementation of the new brush. Compared with the former brush, duodenoscopes cleaned with the new brush had lower odds of contamination with MGOs (adjusted odds ratio 0.25, 95%CI 0.11-0.58; P=0.001) CONCLUSIONS: Use of the new brush in manual cleaning reduced contamination with MGOs and is expected to prevent EAIs. These findings should be confirmed in future prospective randomized studies.


Subject(s)
Duodenoscopes , Magnesium Oxide , Humans , Retrospective Studies , Disinfection/methods , Equipment Contamination/prevention & control , Endoscopy, Gastrointestinal
10.
Asian J Endosc Surg ; 17(1): e13245, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37724691

ABSTRACT

INTRODUCTION: As well as preventing nosocomial and healthcare-associated infections, a reliable and eco-friendly washer for medical equipment would also be safe for the global environment. The aim of this study was to evaluate the efficacy of a newly developed automatic washing system (Nano-washer) that uses electrolyzed water and ultrasonication without detergent for washing endoscopes. METHODS: Patients who underwent laparoscopic lobectomy or laparoscopic colectomy at Nagasaki University between 2018 and 2022 were included. A total of 60 cases of endoscope use were collected and classified according to endoscope washing method into the Nano-washer group (using no detergent) (n = 40) and the manual washing group (n = 20). Protein and bacterial residues were measured before and after washing, using absorbance spectrometry and 16S rRNA polymerase chain reaction. The effectiveness of protein and bacterial removal and endoscope surface damage after washing were compared under specular vision between the groups. RESULTS: Nano-washer did not use detergent unlike manual washing. There was no difference in demographic or clinical characteristics between the groups except for the presence of comorbidities in the lobectomy group (Nano-washer, 85%; manual washing, 40%, P = .031). Compared with the manual washing group, residual protein levels in the Nano-washer group were significantly reduced after washing (lobectomy, 0.956 mg/mL vs 0.016 mg/mL, P < .001; colectomy, 0.144 mg/mL vs 0.002 mg/mL, P = .008). Nano-washer group showed a significant reduction in bacteria between before and after lobectomy (9437 copies/cm2 vs 4612 copies/cm2 , P = .024). CONCLUSION: Nano-washer is a promising, effective, and eco-friendly automatic washing device that is safer and more efficient than manual washing.


Subject(s)
Detergents , Disinfection , Humans , Disinfection/methods , Feasibility Studies , RNA, Ribosomal, 16S , Equipment Contamination/prevention & control , Endoscopes/microbiology
11.
Infect Control Hosp Epidemiol ; 45(1): 100-102, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37534438

ABSTRACT

Initial specimen diversion devices (ISDDs) are a potential solution for reducing blood-culture contamination rates. We report the implementation of an ISDD associated with a sustained reduction in blood-culture contamination rates for >18 months after implementation. We did not observe a clinically significant reduction in inpatient vancomycin usage.


Subject(s)
Blood Culture , Vancomycin , Humans , Vancomycin/therapeutic use , Equipment Contamination/prevention & control , Blood Specimen Collection
12.
Infect Control Hosp Epidemiol ; 45(1): 35-39, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37466074

ABSTRACT

OBJECTIVE: Determination of whether vascular catheter disinfecting antiseptic-containing caps alone are effective at decreasing microbial colonization of connectors compared to antiseptic-containing caps plus a 5-second alcohol manual disinfection. SETTING: The study was conducted in a 718-bed, tertiary-care, academic hospital. PATIENTS: A convenience sample of adult patients across intensive care units and acute care wards with peripheral and central venous catheters covered with antiseptic-containing caps. METHODS: Quality improvement study completed over 5 days. The standard-of-care group consisted of catheter connectors with antiseptic-containing caps cleaned with a 5-second alcohol wipe scrub prior to culture. The comparison group consisted of catheter connectors with antiseptic-containing caps without a 5-second alcohol wipe scrub prior to culture. The connectors were pressed directly onto blood agar plates and incubated. Plates were assessed for growth after 48-72 hours. RESULTS: In total, 356 catheter connectors were cultured: 165 in the standard-of-care group, 165 in the comparison group, and 26 catheters connectors without an antiseptic-containing cap, which were designated as controls. Overall, 18 catheter connectors (5.06%) yielded microbial growth. Of the 18 connectors with microbial growth, 2 (1.21%) were from the comparison group, 1 (0.61%) was from the standard-of-care group, and 15 were controls without an antiseptic-containing cap. CONCLUSIONS: Bacterial colonization rates were similar between the catheter connectors cultured with antiseptic-containing caps alone and catheter connectors with antiseptic-containing caps cultured after a 5-second scrub with alcohol. This finding suggests that the use of antiseptic-containing caps precludes the need for additional disinfection.


Subject(s)
Anti-Infective Agents, Local , Catheter-Related Infections , Catheterization, Central Venous , Central Venous Catheters , Adult , Humans , Anti-Infective Agents, Local/pharmacology , Disinfection , Ethanol , Chlorhexidine/pharmacology , Catheter-Related Infections/prevention & control , Equipment Contamination/prevention & control
13.
Nutr Clin Pract ; 39(2): 437-449, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37635446

ABSTRACT

BACKGROUND: Enteral tube feeding can require considerable amounts of plastic equipment including delivery sets and containers, often disposed of after a single feeding session because of bacterial contamination concerns. The aim of this research was to assess whether reuse of delivery sets and containers for up to 24 h is safe from a microbiological perspective. METHODS: Four enteral tube feeding systems (FS) were tested under hygienic controlled or repeated inoculation challenge conditions using key foodborne pathogens, to assess bacterial growth over time (FS1: ready-to-hang, closed 1-L system with delivery set reused, stored at room temperature [RT]; FS2: a prepared, powdered, open 1-L system with delivery set and container reused, stored at RT; FS3 and FS4: prepared, powdered, open 200-ml bolus systems with delivery set and container reused, stored at RT [FS3] and refrigeration [FS4]). Feed samples were cultured at 0.5, 6.5, 12.5, 18.5, and 24.5 h with >2 Δlog considered significant bacterial growth. RESULTS: Under hygienic control, FS1, FS3, and FS4 were below the level of enumeration (<5 CFU/g) for all bacteria tested, at all time points. In FS2, significant bacterial growth was observed from 18.5 h. Under repeated bacterial inoculation challenge, no significant growth was observed in FS1 and FS4 over 24.5 h; however, significant growth was observed in FS2 after 6.5 h and in FS3 after 10-12 h. CONCLUSION: With hygienic handling technique, there is limited bacterial growth with reuse of delivery sets and containers over 24 h. Refrigeration between feeding sessions and using boluses of reconstituted powdered feed reduce bacterial growth risk.


Subject(s)
Enteral Nutrition , Equipment Contamination , Humans , Enteral Nutrition/methods , Equipment Contamination/prevention & control , Bacteria , Refrigeration , Food Microbiology
14.
J Gastroenterol Hepatol ; 39(1): 7-17, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37859502

ABSTRACT

Gastrointestinal (GI) endoscopy is among the highest waste generator in healthcare facilities. The major reasons include production of large-volume non-renewable waste, use of single-use devices, and reprocessing or decontamination processes. Single-use endoscopic accessories have gradually replaced reusable devices over last two decades contributing to the rising impact of GI endoscopy on ecosystem. Several reports of infection outbreaks with reusable duodenoscopes raised concerns regarding the efficacy and adherence to standard disinfection protocols. Even the enhanced reprocessing techniques like double high-level disinfection have not been found to be the perfect ways for decontamination of duodenoscopes and therefore, paved the way for the development of single-use duodenoscopes. However, the use of single-use endoscopes is likely to amplify the net waste generated and carbon footprint of any endoscopy unit. Moreover, single-use devices challenge one of the major pillars of sustainability, that is, "reuse." In the era of climate change, a balanced approach is required taking into consideration patient safety as well as financial and environmental implications. The possible solutions to provide optimum care while addressing the impact on climate include selective use of disposable duodenoscopes and careful selection of accessories during a case. Other options include use of disposable endcaps and development of effective high-level disinfection techniques. The collaboration between the healthcare professionals and the manufacturers is paramount for the development of environmental friendly devices with low carbon footprint.


Subject(s)
Climate Change , Ecosystem , Humans , Equipment Contamination/prevention & control , Endoscopes , Duodenoscopes , Disinfection/methods , Endoscopy, Gastrointestinal
15.
J Clin Anesth ; 92: 111303, 2024 02.
Article in English | MEDLINE | ID: mdl-37875062

ABSTRACT

BACKGROUND: Earlier studies showed net cost saving from anesthesia practitioners' use of a bundle of infection prevention products, with feedback on monitored Staphylococcus aureus intraoperative transmission. ESKAPE pathogens also include Enterococcus and gram-negative pathogens: Klebsiella, Acinetobacter, Pseudomonas, and Enterobacter. We evaluated whether bacterial contamination of patient nose, patient groin and axilla, anesthesia practitioners' hands, anesthesia machine, and intravenous lumen all contribute meaningfully to ESKAPE pathogen transmission within anesthesia work areas. METHODS: The retrospective cohort study used bacterial count data from nine hospitals, 43 months, and 448 ESKAPE pathogen transmission events within anesthesia areas of 86 operating rooms. Transmission was measured within and between pairs of successive surgical cases performed in the same operating room on the same day. RESULTS: There were 203 transmission events with S. aureus, 72 with Enterococcus, and 173 with gram negatives. ESKAPE pathogens in the nose contributed to transmission for 50% (99% confidence limit ≥45%) of case pairs, on the groin or axilla for 54% (≥49%), on the hands for 53% (≥47%), on the anesthesia machine for 21% (≥17%), and in the intravenous lumen for 24% (≥20%). ESKAPE pathogens in the nose started a transmission pathway for 27% (≥22%) of case pairs, on the groin or axilla for 24% (≥19%), on the hands for 38% (≥33%), on the anesthesia machine for 11% (≥7.6%), and in the intravenous lumen for 8.0% (≥5.3%). All P ≤ 0.0022 compared with 5%. CONCLUSIONS: To prevent intraoperative ESKAPE pathogen transmission, anesthesia practitioners would need to address all five categories of infection control approaches: nasal antisepsis (e.g., povidone-iodine applied the morning of surgery), skin antisepsis (e.g., chlorhexidine wipes), hand antisepsis with dispensers next to the patient, decontamination of the anesthesia machine before and during anesthetics, and disinfecting caps for needleless connectors, disinfecting port protectors, and disinfecting caps for open female Luer type connectors.


Subject(s)
Anesthesia , Cross Infection , Equipment Contamination , Female , Humans , Anti-Bacterial Agents/therapeutic use , Axilla/microbiology , Cross Infection/prevention & control , Equipment Contamination/prevention & control , Groin/microbiology , Retrospective Studies , Staphylococcus aureus , Disease Transmission, Infectious
17.
Compend Contin Educ Dent ; 44(9): 504-508; quiz 509, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37850954

ABSTRACT

All dental healthcare providers need to ensure patient and worker safety by maintaining excellent standards with regard to cleaning and disinfecting treatment rooms and reprocessing critical instruments. Especially in this day and age of heightened infection control concerns, proper cleaning and disinfection protocols are critically important to prevent cross-contamination and maintain hygienic conditions. This article reviews infection prevention strategies in the dental office, beginning with treatment room cleaning and disinfection, which includes maintenance of various types of surfaces and the use of barrier protection, and continuing to the disinfection and sterilization of dental instruments. The article also discusses methods for validating the sterilization process and proper instrument storage.


Subject(s)
Cross Infection , Humans , Cross Infection/prevention & control , Equipment Contamination/prevention & control , Sterilization/methods , Disinfection/methods
18.
Am J Infect Control ; 51(11S): A96-A106, 2023 11.
Article in English | MEDLINE | ID: mdl-37890958

ABSTRACT

BACKGROUND: Semicritical medical devices are defined as items that come into contact with mucous membranes or nonintact skin (e.g., gastrointestinal endoscopes, endocavitary probes). Such medical devices require minimally high-level disinfection. METHODS: Analyze the methods used to reprocess semicritical medical devices and identify methods and new technologies to reduce the risk of infection. RESULTS: The reprocessing methods for semicritical medical devices is described as well as a shift from high-level disinfection to sterilization for lumened endoscopes. CONCLUSIONS: Strict adherence to current guidelines and transition to sterilization for endoscopes is required as more outbreaks have been linked to inadequately disinfected endoscopes and other semicritical items than any other reusable medical devices.


Subject(s)
Cross Infection , Humans , Cross Infection/prevention & control , Sterilization/methods , Disinfection/methods , Endoscopes , Disease Outbreaks , Endoscopes, Gastrointestinal , Equipment Contamination/prevention & control
19.
Gastroenterol Nurs ; 46(6): 455-464, 2023.
Article in English | MEDLINE | ID: mdl-37700439

ABSTRACT

Contamination due to failures or omissions in the reprocessing steps of gastrointestinal endoscopes is common in clinical practice. Ensuring the proper execution of each step is a challenge for reprocessing personnel. This cross-sectional study was conducted in an endoscopy setting between March and May 2021. We performed interviews about reprocessing practices, analyzed the life history of the equipment, and performed inspections through a borescope video of gastrointestinal endoscope channels that were stored and ready for use. A borescope is a complementary tool used to validate endoscope reprocessing, evaluate the internal visualization of channels, and identify changes that can compromise the safety of its use, which are often not detected in the leak test. Thirteen biopsy channels from stored gastrointestinal endoscopes were inspected. We found that 85% had stains and grooves, 69% contained moisture, and 46% had debris. There was at least one noncompliance issue in all of the channels inspected.


Subject(s)
Disinfection , Equipment Reuse , Humans , Cross-Sectional Studies , Endoscopes , Endoscopes, Gastrointestinal , Equipment Contamination/prevention & control